Free Shipping! On order over $50000

What's the difference between parallel flow, counter flow ...

Parallel flow shell and tube heat exchangers. A parallel flow pattern, also referred to as a cocurrent flow, is one in which the shellside and tubeside fluids flow in the same direction. This is widely seen in double-pipe heat exchangers and can be replicated in shell and tube heat exchangers as well, according to Bright Hub Engineering.

Parallel and Counter Flow Designs Heat Exchangers ...

Parallel and Counter Flow Designs Heat Exchangers - Although ordinary heat exchangers may be extremely different in design and construction and may be of the single- or two-phase type, their modes of operation and effectiveness are largely determined by the direction of the fluid flow within the exchanger.

CFD ANALYSIS OF DOUBLE HELICAL PIPE PARALLEL& …

Double pipe heat exchanger . The double pipe or the tube in tube type heat exchanger consists of one pipe placed concentrically inside another pipe having a greater diameter. The flow in this configuration can be of two types: parallel flow and counter-flow. It can be arranged in a lot of series and parallel configurations to meet the different ...

DOUBLE-Pipe Heat Exchanger Experiment - Blogger

Jul 08, 2011· If both the fluids move in the same direction, the arrangement is called a parallel flow type. In the counter flow arrangement the fluids move in parallel but opposite directions. In a double pipe heat exchanger, either the hot or cold fluid occupies the annular space and the other fluid moves through the inner pipe.

Effectiveness Concept for Heat Exchangers - UMass Amherst

Effectiveness Concept for Heat Exchangers The Design Equation for a Heat Exchanger Q H = UA ∆ T 2 – ∆ T 1 ln ∆ T 2 ∆ T 1 = UA ∆ T lm A typical problem in the analysis of a heat exchanger is the Performance calculation. That is, we are asked, given inlet conditions to evaluate how the exchanger performs, that is what are the outlet ...

Chapter 5 HSL - Homepages at WMU

Double-pipe heat exchanger consists of two concentric pipes as shown in Figure 5.1 (a) and is perhaps the simplest heat exchanger. This heat exchanger is also suitable where one of both fluids is at very high pressure. Double pipe heat exchangers are generally used for small-capacity applications (less than 50 m 2 of total heat transfer surface ...

ANSYS Tutorial:CFD Analysis of Double Pipe Counter Flow ...

Apr 30, 2017· Double pipe Counter flow heat exchanger .CFD modeling of heat exchanger, Flow in a double pipe heat exchanger. Double pipe Counter flow heat exchanger .CFD modeling of heat exchanger, Flow in a ...

HEAT EXCHANGERS - جامعة بابل

Two types of flow arrangement are possible in a double-pipe heat exchanger: in parallel flow, both the hot and cold fluids enter the heat exchanger at the same end and move in the same direction. In counter ... that is also applicable to counter flow heat exchangers. But this

Double Pipe Heat Exchangers, Plate Type Heat Exchanger ...

The main advantage of a hairpin / double pipe heat exchanger is that it can be operated in a true counter flow pattern, To get More Efficiency, In the mean Time, it will give the highest overall heat transfer coefficient for the double pipe heat exchanger design. 2. Parallel Flow;- Parallel Flow double pipe heat exchangers are focused to handle ...

Sizing a Heat Exchanger: Double pipe, counter-Flow

Describes how counter-flow is different from parallel flow. Calculates the length of a concentric counter-flow heat exchanger. Describes how counter-flow is different from parallel flow. ... Sizing a Heat Exchanger: Double pipe, counter-Flow is categorized in the following disciplines: ...

Double Pipe Heat Exchanger - University at Buffalo

for the double pipe heat exchanger for countercurrent flow and parallel (or co-current) flow. System: The heat exchanger consists of two thin wall copper tubes mounted concentrically on a panel. The flow of water through the center tube can be reversed for either countercurrent or parallel flow.

Comparison of the overall heat transfer coefficient value ...

double pipe heat exchanger without and with various twisted ... Counter flow, Double pipe heat exchanger, Heat exchangers, Heat transfer co-efficient. 1. INTRODUCTION ... Counter flow c) Cross flow 2.1.1 Parallel flow heat exchanger In a parallel flow heat exchanger, as the name suggests, the two fluid streams (hot and cold) travel ...

What is a Double pipe heat exchanger - webbusterz

Jan 03, 2015· Fin construction details Section of a Double Pipe Heat Exchanger . Double Pipe Exchanger with Finned Pipe Surface . The most widely used double pipe heat exchanger is the hair pin. The high stresses produced by differential thermal expansion between outer and inner pipes are more easily handled.

Heat Transfer/Heat Exchangers - Wikibooks, open books for ...

Counter flow heat exchangers are inherently more efficient than parallel flow heat exchangers because they create a more uniform temperature difference between the fluids, over the entire length of the fluid path. Counter flow heat exchangers can allow the "cold" fluid to exit with a higher temperature than the exiting "hot" fluid.

Double Pipe Heat Exchanger - University at Buffalo

double pipe heat exchanger for countercurrent flow and parallel (or co-current) flow. System: The heat exchanger consists of two thin wall copper tubes mounted concentrically on a panel. The flow of water through the center tube can be reversed for either countercurrent or parallel flow.

Chapter 5 Heat Exchangers - engr.mun.ca

Heat Exchangers 73 individual thermal resistances of the system. Combining each of these resistances in series gives: 1 UA = 1 (ηohA)i 1 Skw 1 (ηohA)o (5.7) where η0 is the surface efficiency of inner and outer surfaces, h is the heat transfer coefficients for the inner and outer surfaces, and S …

(PDF) CHE245 - Lab Report SOLTEQ Concentric Tube Heat ...

Two types of flow arrangement are possible in a double-pipe heat exchanger. In parallel flow, both the hot and cold fluids enter the heat exchanger at the same end and move in the same direction. In counter flow, on the other hand, the hot and cold fluids enter the heat exchanger at opposite ends and flow in opposite directions.

Double Pipe Heat Exchangers

Types of Double Pipe Heat Exchangers : 1. Counter flow 2. Parallel Flow Heat Exchanger. 1. Counter flow : The main advantage of a hairpin or double pipe heat exchanger is that it can be operated in a true counter flow pattern, To get More Efficiency, In the mean Time, it will give the highest overall heat transfer coefficient for the double pipe heat exchanger design.

Summer 2005 Double Pipe Heat Exchanger Experiment

A concentric tube or double pipe heat exchanger is one that is composed of two circular tubes. One fluid flows in the inner tube, while the other fluid flows in the annular space between the two tubes. In counterflow, the two fluids flow in parallel, but opposite directions. In parallel flow the two fluids flow in parallel and in the same ...

HEAT EXCHANGER - ww2.che.ufl.edu

Heat exchanger configurations; parallel vs. counter-current flow ... diameter of for a circular pipe is equal to its diameter. Relationship between Re, Pr, and Nu depends on the system geometry and whether the flow is laminar and turbulent. For example, for a turbulent flow inside a circular pipe,

Heat Exchangers - Exercises - Exeter

Parallel flow in a double-pipe exchanger. Counter-flow in a double-pipe exchanger. Shell and tube heat exchanger with 2 shell-passes and 72 tube-passes. The alcohol flows in the shell and the water in the tubes. Calculate also the exchanger length. Cross-flow heat exchanger with both fluids making one pass. Consider the shell fluid to be "mixed".

Heat Exchanger Flow: Cross flow, Parallel flow, Counter ...

A double pipe heat exchanger can be operated in parallel flow mode as shown in the diagram at the left. Similarly a shell and tube heat exchanger can be operated in approximately parallel flow by having both fluids enter at one end and exit at the other end.

Double Pipe Heat Exchanger Design with Counterflow or ...

Types of Double Pipe Heat Exchangers 1. Counter flow and 2. Parallel Flow Heat Exchanger. 1. Counter flow The main advantage of a hairpin or double pipe heat exchanger is that it can be operated in a true counter flow pattern, To get More Efficiency, In the mean Time, it will give the highest overall heat transfer coefficient for the double pipe heat exchanger design.

(PDF) DESIGN AND OPERATION OF DOUBLE PIPE HEAT EXCHANGER

The double pipe heat exchanger is one heat exchanger pipe inside another larger pipe for either counter flow or parallel flow pattern. The heat exchange duty a llows calculation of the log mean ...

Heat exchanger - Wikipedia

Although double-pipe heat exchangers are the simplest to design, the better choice in the following cases would be the helical-coil heat exchanger (HCHE): The main advantage of the HCHE, like that for the Spiral heat exchanger (SHE), is its highly efficient use of space, especially when it's limited and not enough straight pipe can be laid.

Double Pipe Heat Exchanger, Double Pipe Heat Exchanger ...

Double pipe heat exchanger Design : JC Equipments Pvt Ltd used top rated softwares to design and best quality design engineers to design your double pipe heat exchanger. The heat exchangers are usually designed in a hairpin shape with ASME Code and will typically be either counterflow or parallel …

CFD ANALYSIS OF DOUBLE PIPE PARALLEL FLOW HEAT …

CFD ANALYSIS OF DOUBLE PIPE PARALLEL FLOW HEAT EXCHANGER 1 DIVI VENKATA PRASHANTH, 2 GOROGINAM SANTHI 1 Pg Scholar, Department of MECH, BRILLIANT GRAMMER SCHOOL EDUCATIONAL SOCIETY'S (BRIG),JNTUH,Hyderabad.Abdullapurmet (V), Hayathnagar (M), Hyderabad, Telangana, India. 2 Assistant Professor, Department of MECH, BRILLIANT GRAMMER …

Solved: In An Industrial Facility A Counter Flow Double Pi ...

In an industrial facility a counter flow double pipe heat exchanger uses superheated steam at a temperature of 250 i 1/2 C to heat feed water at 30 I 1/2 C. The superheated steam experiences a temperature drop of 70 i 1/2 C as it exits the heat exchanger.

Double Pipe Heat Exchanger - University at Buffalo

Double Pipe Heat Exchanger Jan. 22, 2003 Today's Lecture Lab Teams and Schedules Double Pipe Heat Exchanger Lab Teams and Schedules Heat Exchanger Double Pipe Heat Exchanger Two Types of Flow Counter-Current Hot stream enters near cold stream exit Co-Current or Parallel Hot stream and cold stream enter near each other, and exit near each other.

What is the temperature profile of a double pipe heat ...

A double pipe heat exchanger temperature profile is exactly what is taught in academia - for a co current exchanger - two lines exponentially going towards each other . For a counter current exchanger two curved lines which look parallel to each o...

double grinding wheelsdouble roll crusher machine 2pg400detailed specifiions of double roll crusher in indiadouble stone fireplacehenan 2014 double mobile jaw crusher hot sale high efficientdouble toggle jaw crusher supplierdouble roller crusher manufacturers indiadouble ended pedestal grinderrollers crusher doublecrushers double togglemorgardshammar 84 x 60 double toggle jaw crushersdouble roll coal crussersingle toggle versus double toggle jaw crushersdouble toggle jaw crusher mechanismdouble pipe counter paralleldouble roller crusher technology